Samlex PST inverter remote port: wiring and phone control

samlex

Samlex RJ11

  • PST-600 (RC-15A remote)
  • PST-1000 (RC-15A remote)

Samlex’s PST-600 and PST-1000 pure sine inverters have an RJ12 jack for the RC-15A wired remote, the small panel with an ON/OFF push button and three LEDs. That jack is all our Inverter Controller needs. There is no digital communication on it: the push button connects two wires to switch the inverter, and the inverter lights the LEDs on separate wires.

Front panel of a Samlex PST-1000 with the remote jack (10) highlighted below the ON/OFF rocker switch

The remote jack (10) on the front of a PST-1000. Drawing from Samlex’s manual.

Switching is a toggle: a short press turns the inverter on, the next one turns it off. Our controller does the same thing, and reads the green POWER LED to tell you whether the inverter is actually running. For the remote to work, the ON/OFF switch on the inverter itself has to be in the ON position. Samlex points out that the inverter still draws a little current when it’s switched off with the remote, so if you leave the van for a while, turn it off on the inverter too.

Which wire does what

Samlex publishes the pinout of the jack on the back of the remote. Looking into that jack, the pins are numbered 1 to 6 from left to right:

  • Pin 1: red OVER LOAD LED
  • Pin 2: toggle (the push button)
  • Pin 3: ground (common)
  • Pin 4: battery
  • Pin 5: green POWER LED
  • Pin 6: red OVER TEMP LED

The cable that comes with the remote is rolled over, so on the inverter end everything is mirrored: pin 2 on the remote is pin 5 on the inverter, and so on. What the manual doesn’t say is whether the button connects the toggle pin to ground or to battery. That’s the one thing you’ll need to find out with the multimeter.

Checking it with a multimeter

Cables and remote revisions differ, so check before you solder anything. Unplug the cable from the remote and put your multimeter in continuity mode on the remote’s own jack. Hold the push button down and check pin 2 against pin 3, then against pin 4: one of the two should beep only while the button is held. That’s your switch pair. Then plug the cable back into the inverter only, and briefly touch those two wires together at the loose end: the inverter should start, and the next touch should stop it. To check the LED line, put the multimeter on DC and measure between the POWER LED wire and ground: you should get a reading while the inverter runs, and none when it’s off. If all of this matches, you’re good to go.

One thing to watch out for: this page is about the PST-600 and PST-1000 with the RC-15A. Bigger Samlex inverters use different remotes, and we don’t know enough about those yet to say whether they work the same way.

Further reading

We haven’t had a Samlex on our own bench yet. The pinout on this page comes straight from Samlex’s own RC-15A manual. They’re worth a read if you want the details:

Samlex® is a trademark of its respective owner. VanTurtle is not affiliated with, endorsed by, or sponsored by Samlex. We only mention them to show compatibility.

Switch it from your phone

Our Inverter Controller plugs into the Samlex PST remote port and lets you switch it over Bluetooth, from the Home app on iPhone or Device Controls on Android. No cloud or hub, so it keeps working off-grid. Tell us your model when you order and we’ll set it up for this pinout before it ships. From €19,99.