Ective inverter remote port: wiring and phone control
Ective RJ11
- SI series (RC 1 remote)
- TSI series (RC 2 / RC 3 remote)
- CSI series (RC 2 / RC 3 remote)
- SSI series (RC 4 remote)
Ective’s SI, TSI, CSI and SSI inverters have an RJ12 port for their wired remotes (RC 1 to RC 4), connected with the 3 m six-wire cable that Ective calls an ISDN cable. That port is all our Inverter Controller needs to switch the inverter. According to Ective’s own manual, the remote is wired in parallel with the on/off switch on the inverter, so the switch in the remote simply connects two wires.
The remote control port (4) on an SI 15, 20 or 25. The other SI and TSI models have it on the front too. Drawing from Ective’s manual.
The RC 1 has a plain ON/OFF switch, the RC 2, 3 and 4 have an ECO/OFF/UPS switch. Both ECO and UPS close the same two wires, and the switch latches: the inverter stays on for as long as those wires are connected. Our controller does the same thing. For the remote to work, the main switch on the inverter itself has to be off.
There is one catch. The lights and bar graphs on the Ective remotes aren’t driven by a simple LED line we can read; the inverter sends them as data. That means our controller can switch your Ective on and off, but it can’t read back whether the inverter is actually running.
Which wire does what
The on/off switch sits on pins 1 and 2, the two positions at one edge of the plug. Different sources count the pins from different sides of the jack, so which edge that is depends on how you look at it, and we don’t know the wire colours on Ective’s cable yet. The multimeter check below takes care of that. The other four wires carry the display data and its power, and should be left alone.
Checking it with a multimeter
Cables and remote revisions differ, so check before you solder anything. Unplug the cable from the remote and put your multimeter in continuity mode on the remote’s own jack, or on a cable plugged into it. Look for the pair at one of the two edges that beeps only while the remote’s switch is in ON (or ECO or UPS), and stops beeping in OFF. That’s your switch pair. To be sure, connect those two wires together at the loose cable end that goes to the inverter, with the inverter’s main switch off: the inverter should start. If it does, you’re good to go.
Two things to watch out for. On a combined inverter and charger like the SSI, one owner noticed that with shore power connected and the inverter switched on, it runs from the battery first. So switch it off when you want to charge from shore power. And the newer PRO series (TSI PRO, CSI PRO and SSI PRO) uses the RC PRO, which has a push button that steps through the modes instead of a latching switch. We don’t know enough about that one yet, so this page doesn’t cover it.
Further reading
We haven’t had an Ective on our own bench yet. The pinout on this page comes from an SSI 30 owner who measured the remote cable and has been switching their inverter through a relay ever since, together with Ective’s manual, which confirms the remote works in parallel with the inverter’s own switch. These are worth a read if you want the details:
- Camper-bauen forum: Pinbelegung Fernbedienung Ective SSI 30 (German)
- Akkudoktor forum: Ective Wechselrichter Protokoll & Belegung (German)
- Photovoltaikforum: Ective CSI series remote (German)
- Ective RC series remote manual (PDF)
- Ective RC PRO remote manual (PDF, German)
- Ective SI and TSI series manual, German and English (PDF)
Ective® is a trademark of its respective owner. VanTurtle is not affiliated with, endorsed by, or sponsored by Ective or batterium GmbH. We only mention them to show compatibility.
Switch it from your phone
Our Inverter Controller plugs into the Ective remote port and lets you switch it over Bluetooth, from the Home app on iPhone or Device Controls on Android. No cloud or hub, so it keeps working off-grid. Tell us your model when you order and we’ll set it up for this pinout before it ships. From €19,99.