Renogy P2 inverter remote port: wiring and phone control

renogy

Renogy RJ11

  • RNG-INVT-700-P2
  • RNG-INVT-1000-P2
  • RNG-INVT-2000-P2
  • RNG-INVT-3000-P2
  • RIV1210PU-126 / RIV1220PU-126 / RIV1230PU-126
  • Newer 1000W with 8-pin RJ45 remote port

Renogy’s P2 pure sine inverters have a remote control port on the front, meant for the small wired remote with the ON and ERR lights that comes in the box. That port is all our Inverter Controller needs. There is no digital communication on it: the remote’s rocker switch connects two wires to keep the inverter on, and the inverter lights the two LEDs on the remote.

Renogy 2000 W P2 pure sine inverter seen from the AC side, with the Remote Control Terminal highlighted below the USB port and next to the ON/OFF/REM switch

The remote control port on a Renogy P2 (24 V 2000 W model shown). Drawing from Renogy’s manual.

The port is an RJ12 (six positions, six wires), and Renogy ships a 5 m RJ12 cable with the remote. The rocker is a latching switch, so the inverter stays on for as long as the two wires are connected and turns off when they’re released. Our controller does the same thing, and reads the green power LED to tell you whether the inverter is actually running. For any of this to work, the switch on the inverter itself has to be in the REM position, not ON.

Which wire does what

Different sources count the pins from different sides of the jack, so we’d rather go by wire colour. On the cable that comes with the remote:

  • The middle two wires, red and green, are the on/off switch
  • Yellow is the power LED (green light on the remote)
  • Black is the alarm LED (red ERR light)
  • White and blue, the outer two, are ground

Checking it with a multimeter

Cables and remote revisions differ, so check before you solder anything. Unplug the cable from the remote and put your multimeter in continuity mode. Red and green should beep only while the rocker is in the ON position. Then, with the inverter switch in REM, connect red and green together at the loose cable end (that’s all the rocker does) and the inverter should start. With the multimeter on DC, measure between yellow and one of the outer ground wires: you should get a reading while the inverter runs, and none once you separate red and green again. If both of these match, you’re good to go.

One thing to watch out for: some Renogy models also have a separate RS485 COMM port. That’s a data connection our controller doesn’t use, so don’t confuse it with the remote port. Older 1000, 2000 and 3000 W Renogy inverters with a built-in transfer switch (RIV1210PU-126 and its bigger siblings) use the same 6-wire remote as the P2 series.

Newer 1000 W models with an 8-pin port

Some newer Renogy 1000 W inverters have an 8-pin RJ45 socket for the remote instead of the 6-pin one. The remote looks much the same, but it has a buzzer as well, which is why it needs the extra pins. Even Renogy support only had the 6-pin pinout at hand, so one owner measured the 8-pin socket themselves:

  • Pins 3 and 5: the on/off switch
  • Pin 2: green power LED
  • Pin 4: red alarm LED
  • Pin 7: ground for the LEDs

We expect the switch to latch just like on the 6-pin remote, and our controller reads the green LED the same way. It’s one measurement, and we don’t know which end of the socket they counted from, so do the same multimeter check as above. With the cable unplugged from the remote and the rocker ON, the switch pair beeps; with the inverter running, the green LED pin gives a reading against ground. Then connect the switch pair at the loose end that goes to the inverter (with its switch in REM) and it should start. If the numbers don’t line up, count from the other side of the plug.

Further reading

We haven’t had a Renogy on our own bench yet. The pinout on this page comes from the remote’s circuit diagram, which Renogy support shared with a customer, and three owners who traced and wired their own remotes. They all agree. The 8-pin pinout comes from a fourth owner, in the same thread. These threads are worth a read if you want the details:

Renogy® is a trademark of its respective owner. VanTurtle is not affiliated with, endorsed by, or sponsored by Renogy. We only mention them to show compatibility.

Switch it from your phone

Our Inverter Controller plugs into the Renogy remote port and lets you switch it over Bluetooth, from the Home app on iPhone or Device Controls on Android. No cloud or hub, so it keeps working off-grid. Tell us your model when you order and we’ll set it up for this pinout before it ships. From €19,99.